Hybrid Recommended Usage
Waterproof Hybrid Flooring is recommended for use in internal residential or commercial areas including, but not limited to, living areas, kitchens, bedrooms, hallways and stairs. If installed in wet areas, such as bathrooms or laundries, installation must be according to installation instructions, wet areas not included are areas/rooms with built in drains, such as showers or sauna, warranty will be void if floor installed in areas/rooms with built in drains.
Heavy and bulky objects, such as an island bench, should not be placed on floating floors.
If this flooring is intended to be installed over an existing wooden floor, it is recommended to repair any loose boards or squeaks before you begin installation.
Storage:
Ensure the environment resembles installation conditions (20°C and 40-60% humidity) to avoid material damage. Cartons should be placed in the installation area and remain unopened until commencement of installation.
Heated Subfloors
Most Hybrid Flooring can be installed over a heated slab.
Ensure the radiant heat surface temperature never exceeds 27°C (81°F). Before installing over newly constructed radiant heat systems, operate the system at maximum capacity to force any residual moisture from the cementitious topping of the radiant heat system. The maximum moisture content of the screed is 1.5% (CM method). Shut down the floor heating at least 48 hours prior to installation. Make sure that the temperature in the room is at least 15°C (60 °F) during installation. It is recommended that the radiant heat be applied in a gradual manner after installing the flooring.
Shrinking between boards, cracking and minor cupping can be expected when installing hydronic underfloor heating and does not constitute as a product defect.
If the flooring product has a 5G or drop locking system and is floated over a heated slab it is required that Crosslinked PVA glue be used as per the regular tongue and groove installation. No other form of underfloor heating is recommended.
Subfloor Preparation
Ensure the subfloor is flat and free from debris. For floating floors this generally does not exceed 2mm beneath a 1m long straight edge. For concrete subfloors a moisture barrier is required.
After Installation
Direct sunlight should be minimised with window coverings to prevent heat-related damage.
Never use any of the following products (or similar in nature) on your floor: ammonia-based cleaners, acrylic finishes, wax-based products, bleach, polishes, oil soap, abrasive cleaning soaps, or acidic materials such as vinegar. Many of these products pit or etch the finish of your flooring or prevent the proper use of recommended maintenance materials.